Q = Do I need to clean my
Oceanus 1?
A = Yes, you should clean your
Oceanus 1 completely between each crop.
There are several cleaning solutions available in the market, just
ask your local dealer. You can also use a few drops of
antibacterial handsoap to clean the Oceanus 1.
Just make sure you thoroughly rinse (minimum of 3 times) the
Oceanus 1 to remove all soap and debris before
using.
Q = Is there some way I can test
my Oceanus 1 to make sure it's functioning
properly?
A = Yes, there is! Follow the
test procedure below:
Oceanus 1 test
procedure:
Equipment needed:
- 120 volt power
- 120 volt night light or 120 volt
fan or 120 volt circuit tester
Testing process:
- Place the Oceanus 1 on its backside with the
24 hour clock facing up. Position both floats in the 'UP'
position, "towards the black lid".
- Plug the 120 volt night light or 120 volt
circuit tester into the 'DRAIN' side (right side of the clock) of
the Oceanus 1 controller. Turn the 24 hour
clock dial to function in the 'DRAIN' cycle (white arrow pointing
to the black part of the dial). Plug the Oceanus
1 into a 120 volt source, and the night light/tester will
illuminate. Push the 'TOP' float that is closest to
the lid towards the bottom of the bucket and wait five (5) seconds
then push the 'LOWER' float towards the bottom of the
bucket wait five (5) seconds and the light/tester will turn
off.
- Unplug the Oceanus 1 from the 120 volt source
and move the light/tester from the 'DRAIN' side to the 'FILL' side
(left side of clock) of the Oceanus 1. Place
both the 'TOP' and 'LOWER' floats in the down
position "towards the bottom of the Oceanus 1".
Turn the 24 hour clock dial to function in the 'FILL' cycle
(white arrow pointing at the orange part of the dial). Then
plug the Oceanus 1 into the 120 volt source and
the night light/tester will illuminate. Push the 'LOWER'
float of the Oceanus 1 towards the top of the of
the bucket wait five (5) seconds and push the 'TOP' float
towards the lid and wait five (5) seconds and the light/tester will
turn off.
- To verify that the timer is working properly, plug a fan or
test light into the DRAIN side and have both floats in the UP
position and the arrow on the timer pointing towards the orange
FILL ring (trippers are pushed to the inside of the timer).
Then allow the timer to operate (do not touch clock dial) on its
own. When the timer goes into the DRAIN function (trippers are
pushed to the outside covering the orange ring) the fan or test
light will be ON. This test verifys that the timer is
operating properly.
If the Oceanus 1 has functioned as specified
above, then it is working properly.
If for some reason the Oceanus 1 functions
differently then above, please call the Titan Controls hotline-
toll free at 888.808.4826 and we'll
be happy to help you out.!