Titan Controls® Zephyr™ 2 - High Temperature Shut-Off with Delay

Part #{{activeImage.ParentId}}
Titan Controls® Zephyr™ 2 - High Temperature Shut-Off with Delay
Part #{{activeImage.ParentId}} Download Image
Titan Controls® Zephyr™ 2 - High Temperature Shut-Off with Delay
Controller turns off your lights if high temperature exceeds set point. Built-in 1 – 30 minutes Hot Start delay with HOLD feature. 6 foot temperature probe is accurate to within 2° F. Protects your garden & your plants. Enclosure resists dust, rust and moisture. 15 Amps maximum/120 Volts/60Hz.

  • Zephyr 2 turns off your lights if your gardens temperature exceeds the set point
  • US and Canadian ETL listed for use in commercial applications
  • Built in 1 minute to 30 minute delay with 'HOLD' feature
  • 6 foot temperature probe is accurate to within 2° Fahrenheit
  • Protects your garden and keeps your plants safe
  • Plastic enclosure protects internal components from dust and moisture
  • 15 Amps/120 Volts/60 Hz
  • 2 year warranty
702750 - Titan Controls Zephyr 2 - High Temp Shut Off
Download Application Diagram (PDF Document)
Download Instructions (PDF Document)
702750 - Titan Controls Zephyr 2 - High Temp Shut Off
  EACH CASE PALLET
Upc: 870883000158
Quantity:
Volume (cf): 0.043
Dim Weight (in3/lb): 0.3833
Weight (lb): 0.55
Length (in): 5.4
Width (in): 5.1
Height (in): 2.7
I have set my "High Temp" value at 100°F and my "Start Delay" value at 15 minutes. The sensor indicates that 100°F has been achieved. The outlet is shut off. What regulates the outlet regaining power? Is it the temperature reading 90°F (automatic 10°F cool down programmed into the unit) or the preset value of 15 minutes?
Both, but the temperature reading is the overriding factor. The unit will only turn back on if a reading of 90°F has been achieved and the allotted time has elapsed. If the allotted time has elapsed but the 10°F cool down has not been achieved, the unit will not turn back on.
If the Zephyr 2 unit is set to "Hold Restart", how does the unit turn on in the first place since it needs the manual override?
As long as the temperature shut off has not been engaged, the unit will turn on immediately regardless of the "Hold Restart" setting being enabled.
Does the high temp shut off also delay the starting of your lights in the case of a power outage? Or, does it delay the start of the lights in the case of over-heating? If you wanted to set it to "HOLD" so that you were required to manually re-start the lights, would it not re-start at all in the case of a power outage?
The delay feature is for power outages, though it will delay "turn on" if time elapsed for cool down is shorter than the delay setting. If set in "hold restart", once turned off it will not restart until manually reset.

    Sort By:
   Brand:
    Category:
Sorry No Results Found...
Title MSRP Wish List
{{part.PartId}}
{{part.PartId}}
{{part.Name}}
{{part.Name}}
{{part.Message}}
NEW
{{Sunlight.Web.Utility.GetFormattedPrice(part.EachMsrp)}}
 Wish List
 Find Retailer
Your results were limited to 50 items. You may want to be more specific.